SPECIFICATIONS
ECOSIL
Download Word Document
Section 071000 Water Repellent
- Water repelling, penetrating coating applied to exterior and interior masonry, concrete, and cement plaster surfaces.
- Perform work in accordance with manufacturers printed instructions.
Maintain one copy of document on site.
- Manufacturer: Company specializing in manufacture of water repellent coatings with five years minimum experience.
Applicator: Certified and approved by manufacturer.
- Submit product data information.
Include details of product description, tests performed, limitations to coating, cautionary procedures required during application, and chemical properties
Submit manufacturers installation instructions.
Submit manufacturers certificate that products meet or exceed specified requirements and that their application was according to manufacturers recommendation.
Submit manufacturers certificate that products supplied comply with local regulations controlling the use of volatile organic compounds (VOC).
Submit manufacturers test and inspection reports.
- PRE-INSTALLATION CONFERENCE
- Convene a pre-installation conference one week prior to commencing work of this Section.
Review installation procedures and coordination required with related work.
- Apply coating to 24 sq ft area of each surface to be waterproofed where directed by Architect.
- Provide manufacturers 5-year warranty for materials.
- Comply with all current federal, state, and local volatile organic compound (VOC) regulations.
- ENVIRONMENTAL REQUIREMENTS
- Do not apply coating when ambient temperature is lower than 40 degrees F or higher than 100 degrees F.
- EPRO Services, Inc. 800-882-1896.

A. ECOSIL, a water-based polydimethyl siloxane and polyamino siloxane blend with the following specifications.
- Verify joint sealants are installed and cured.
Verify surfaces to be coated are dry, clean, and free of efflorescence, oil, or other matter before application of coating.
Beginning of installation means acceptance of substrate.
- Remove loose particles and foreign matter.
Remove oil or foreign substance with a cleaner, which will not affect coating.
Protect adjacent surfaces not scheduled to receive coating.
If applied on unscheduled surfaces, remove immediately, by approved method.
- Field inspection and testing will be performed.
Manufacturer of water repellant coating shall provide the inspection services as required.
- Delay work until substrate is cured a minimum of 48 hours.
Apply coating in one liberal spray application from the top down, chasing vertical and horizontal spray overlaps with a roller.
- Protect adjacent surfaces from damages and stains.
Clean materials from surfaces where inadvertently applied.
Protect finished installation.
...